AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |
Back to Blog
Fire Alarm Drawing Software4/20/2021
Edraw fire and emergency layout software provides you lots of symbols, including fire extinguisher, fire hydrant, smoke detector, sprinkler, ventilation opening, a fire alarm bell, etc.You will surely make your house and work environment safer if you draw a fire and emergency layout and display it others.Also, you will easy to find out the potential safety hazard when drawing the fire and emergency layout with Edraw software.
Edraw offers an easily way to create fire and emergency layouts that shows the locations of fire alarms, extinguishing equipment, escape routes and exits. In the pre-defined template, you can directly use the ready-made shapes and symbols, so you can get started quickly. Once you finish the plan, you can easily print it or exported to other formats with only a single click. Everybody can design a Fire and Emergency layout in just minutes. EdrawMax is an advanced all-in-one diagramming tool for creating professional flowcharts, org charts, mind maps, network diagrams, UML diagrams, floor plans, electrical diagrams, science illustrations, and more. ![]() You will be off to a great start if you can obtain full CAD quality plans. Understandably, these may not always be available so hand drawn sketches will also suffice as long as they are an accurate representation of the building. The positions of all the fire alarm control panels, repeater panels and all associated power supplies. Also include the battery cabinets, if these are installed and remote to the panels. Use a different symbol for each type of device, these can be very simple if youre not working on CAD. The main thing to remember here is to include a key or legend, detailing what each of the symbols are. Add all address numbers (including loop designation) for addressable systems, and all positions of end of line resistors. This is usually just noted as EOL next to the relevant devices. Its useful to also state the circuit that the EOL relates to, e.g. EOL Z1 for the end of the Zone 1 circuit or EOL SCCT2 for the end of sounder circuit 2. These are all other items pertaining to the fire alarm system installed. Where short circuit isolators are integral to some or all of the devices, it may be clearer to add this to the description in the key. Fire Alarm Drawing Software Manual Call PointE.g. Manual Call Point cw integral short circuit isolator).Also add the routes of any aspirating pipework installed, and include the position of the sampling points and any low level test points that may be present. Add a general note to all your drawings detailing the cable type and size. If the note All cable 2c 1.5mm fire rated (red) is added, then just any cable that doesnt fall into this description can be individually identified on the drawing, i.e. The actual routes of cables must be added. A simple schematic showing just the order in which devices are connected is not sufficient to comply with the recommendations. ![]() Where multiple cables run together, it is acceptable to show these separately and with enough space to be able to identify separate cables on the drawing. Also add the cable from the mains supply to the control equipment, its also good practice to note the distribution board reference andor circuit breaker number on the drawings too. These can then be easily referenced in the remaining completion paperwork. These can be listed on separate forms, but as you have drawings showing a plan of the premises its usually clearer to add them here. Its good practice to also add details of your sound level meter, including serial number and calibration date too. If youre not using CAD, a specialist fire alarm CAD company will be able to help create your bespoke templates for fire alarm installations. Without one, it should be noted as a major non-compliance during routine maintenance. Electrical Trade Magazine is fully GDPR compliant, click here to view our privacy policy.
0 Comments
Read More
Leave a Reply. |